Skip to main content

Advanced Package Settings View

AdminStudio 2025 R2 | 30.0 | Repackager

This feature is available in AdminStudio Professional and Enterprise Editions.

From the Advanced Package Settings view, you can configure several additional settings that may apply to your repackaged setup.

Select the appropriate options:

Package Conversion Options

The following package conversion options are available:

OptionDescription
Use Editor path variables instead of physical source pathsWhen storing files in the InstallShield Editor project ( .ism ), the Wizard uses path variable locations whenever possible.
Display only the Welcome dialog box during installationOnly the Welcome dialog box is displayed when the Windows Installer package is run on a target machine. If this option is unchecked, the default UI sequence is displayed when the setup is installed.
Replace files with merge modules wherever possibleFollowing best practice rules, Repackager replaces components with comparable merge modules whenever possible.
Use the language captured by the Repackager as the language of the setupWhen selected, the target package's language will be the language detected by Repackager (as displayed in the Captured Installation view).
Include files from Setup Intent scanAny files identified when running the Setup Intent Wizard will be included in the package (unless you have manually excluded them from the project).

Component Settings Options

The following component settings options are available:

OptionDescription
Mark components destined for the System folder as permanentExecutable files installed to the system folder (System32Folder) are marked as Permanent files and will not be uninstalled when the package is uninstalled. This eliminates ICE09 validation errors.
Mark components destined for the CommonFiles folder as sharedExecutable files installed to the CommonFilesFolder (or a subfolder of CommonFilesFolder) are marked as shared files. This ensures that these components can coexist with DLLs installed by previous setups.
Map registry data to the appropriate COM tablesSetting this option reduces the number of ICE33 warnings that can occur during package validation, resulting from data not being mapped to the appropriate MSI tables.
Map registry data to the appropriate ODBC tablesIf selected, ODBC-related registry data is mapped to ODBC tables instead of the Registry table. This data will only function correctly if Windows Installer supports the ODBC resource being mapped; it is highly recommended that you do not enable this option if you are unsure whether the ODBC resources are supported correctly by Windows Installer.
Map NT Service events to the ServiceControl tableIf selected, NT Service–related registry data is mapped to ServiceControl table instead of the Registry table.